SGC Dock

Manufacturer: Gas Clip Technologies
Part Number: SGC Dock
Order / Quote

Gas Clip Technologies SGC Dock is an all in one docking station designed for maximum testing efficiency and portability. Housed in a rugged Pelican© case with robust USB memory, this station will be able to accurately test and record all monitor data while reducing the testing time and gas usage.

Traditional docking stations are only designed to test one instrument at a time, resulting in time consuming testing periods as well as unnecessary usage of testing gas. Gas Clip Technologies has significantly improved both testing time and test gas usage with the SGC Dock; users can now test 4 instruments simultaneously saving both time and money.

Each SGC Dock comes with the following standard features:

  • Test 4 units at one time, up to 12 instruments in a minute
  • Easy 1 button operation
  • Robust rechargeable internal battery, hundreds of tests before recharging
  • Internal gas cylinder regulator and pressure gauge
  • 2 GB USB memory for bump test and event log storage
  • Optional unit configuration and firmware updates via GCT Manager Software
  • Rugged Pelican© case or Wall Mount Dock
  • No computer required to operate

Size:  85.6 mm H x 50 mm W x 29.2 mm, D 3.37 in H x 1.97 in W x 1.15 in D

Weight:  76g 2.7 oz

Humidity:  5% to 95% non-condensing relative humidity

Alarms:  Visual, vibrating, audible (minimum 95dB)

Tests:  Full function self-test on activation and every 20 hours; continuous automatic battery tests

Operational Life:  Two years

Ratings:  EMC Directives 2004/108/EC IP 67

Certifications:  Standard(s): UL-913 & CAN/CSA-C22.2 No. 157 Class 1 Divisions 1 & 2, Groups A, B, C and D ATEX: II 1 G Ex ia IIC T4 IECEX: EX ia IIC T4

Warranty:  2 years from activation, 1 year shelf life

H2S:  Measuring range: 0-100 ppm, Low alarm limit: 10 ppm, High alarm limit: 15 ppm

CO:  Measuring range: 0-300 ppm Low alarm limit: 35 ppm High alarm limit: 200 ppm

O2:  Measuring range: 0-30% Low alarm limit: 19.5% High alarm limit: 23.5%

Notes:  Real-time gas display or time remaining; Calibration optional; Adjustable alarm set points and bump check reminder 

Unit Configuration/Firmware Updates: In order to keep your fleet of gas detectors compliant with specific settings, we allow for the SGC Dock to program each unit during either bump testing or calibration. The programmable fields are as follows: User ID, Calibration Interval, Bump Interval, Self-Test Interval, Low Alarm, High Alarm, Show Sensor Readings, Hide Bump Due LED and Hide Clock. For example, if your company or facility requires each detector on site to have specific alarm set points and a bump test interval, instead of programming each unit individually, the instruments can be group programmed while simultaneously bump testing (4 units at a time per dock) using our GCT Manager software. As firmware updates become available, we can program each SGC Dock to update units during bump testing and calibration. Facility safety standard compliance for single gas detectors is now easily achievable.

Event Data and Record Storage:  In addition to performing tests, unit configurations and firmware updates, the SGC Dock also stores important information about both the docking station and units tested. All tests performed on the docking station can be accessed from either the USB directly or using the GCT Manager software. Each bump test and calibration event is recorded and logged by date, time and serial number. Along with the test records, the individual event logs from each unit are saved. At the time of the test, the detector transmits its’ event log to the memory. By default, the station will save the previous 10 event logs.

Download
Download
Download