Ventis Pro Series, Pro4

Manufacturer: Industrial Scientific Corp
Part Number: Ventis Pro4
Order / Quote

The Ventis™ Pro Series has you covered whether you need unique four-gas or expanded five-gas sensor options, all in the most configurable multi-gas monitors on the market.

  • LENS™ Wireless allows personal monitors to communicate with area monitors.
  • See gas readings and alarms from connected peers in LENS Wireless groups.
  • Flexible sensor configurations detect up to four gases.
  • Custom start-up messages, alarm action messages, and acknowledgeable gas alerts.
  • Man-down alarm and dedicated panic button.
  • User and site tracking with iAssign™ Technology
  • Rugged IP68 water and dust rating and Guaranteed for Life™ warranty.
  • Available with or without a pump.
  • Dock overdue and maintenance reminders.
  • iNet ® and DSX™ Docking Station ready.
  • Compatible with Ventis MX4 accessories including Ventis Slide-on pump.

Display Monochrome LCD with automatic backlight

User interface buttons Three (power button, enter button, and panic button)

Case materials Polycarbonate with static-dissipative protective rubber overmold

Alarm signals:

Visual (two red and two blue lights);

Audible (95 dB at a distance of 10 cm [3.94 "], typicala );

Vibration

Dimensions 104 x 58 x 36 mm (4.09 x 2.28 x 1 42 ")

Weight 200 g (7.05 oz.), typicalb

Ingress protection IP68 at 1.5 m (4.9 ′) for one hour Pump With 0.3175 cm (0.125 ") inside diameter sample tubing, sustains a continuous sample draw for up to 30.48 m (100 ').

Temperature range c and d -40°C to + 50 °C (-40 °F to + 122 °F)

Humidity ranged 15−95 %

Relative humidity (RH) noncondensing (continuous)

a.  May vary based on in-field conditions.

b.  May vary based on installed components.

INDUSTRY DESCRIPTION HAZARD
Oil & Gas Refining Standard 4-Gas + SO2 SO2 released when oil burns
Oil & Gas Exploration Standard 4-Gas + CO2 CO2 used in fracking
Fire Fighting Standard 4-Gas +HCN HCN release in burning plastics
Power Generation Standard 4-Gas +SO2 Burning coal or oil for fuel
Refrigeration NH3 or CO2 NH3 and CO2 are coolants
Gas Utility CH4, IR, CO, O2 High-range CH4 detection
Steel CO, H2S, SO2, NH3 Four toxics
Coal Mining CH4 IR (Dual Range) One instrument for personal protection and seal checking
Metal Mining Standard 4-Gas + HCN Cyanide used to separate gold from rock