Manufacturer: Arizona Instrument
Order / Quote
The J405 is designed to be easy to operate for quick and accurate analysis of mercury vapor levels.
Key Features
- Much lower detection levels than the previous Jerome® models
- 3.5" (9 cm) backlit display, showing everything you need to be confident in the instrument, including 5/8" (1.6 cm) tall character readout, battery charge indicator, and sensor saturation percentage
- Choice of units for results: micrograms per cubic meter (μg/m3) (default) or milligrams per cubic meter (mg/m3)
- Easy to understand diagnostic and error detection
- Auto zero bridge adjustment
- Updated electronics including 24-bit a/d conversion and on-board storage for 20,000 samples
- Controlled temperature film heat ensures the sensor removes all mercury and returns to its original state
- The Jerome® J405 can be operated for 24 hours from the internal 12V battery source or it can be operated using the external AC power supply/charger
Display Range
- 0.5 μg/m3 to 999 μg/m3
- 0.001 mg/m3 to 0.999 mg/m3
- Sample values below 0.5 μg/m3 or 0.001 mg/m3 will be recorded and displayed as 0.00 μg/m3 or 0.000 mg/m3 respectively by the J405. Sample values above 999 μg/m3 (0.999 mg/m3) will be recorded and displayed as “High Concentration.”
Resolution
- 0.01 μg/m3 Hg
- 0.001 mg/m3 Hg
Response Time
- Sample mode: 17 seconds
- Survey mode: 2 seconds
Flow Rate
- 750 ± 50 cc/min (0.75 ± 0.05 liters/min)
Power Requirements
- 12 VDC for the instrument (provided by the internal battery AC power supply/charger, external battery pack, or car accessory adapter)
- 100-240VAC, 47-63Hz, 3.2A for the AC power supply/charger
Fuse
- Auto-resetting fuse
Internal Battery Pack
- Rechargeable nickel metal hydride (NiMH)
Operating Environment
- 0° to 45° C, non-condensing, non-explosive
Case construction
- Aluminum, powder coated
Dimensions
- 11" L x 6" W x 6.5" H (28 cm L x 16 cm W x 17 cm H)
Weight
- 5.3 lbs. (2.4 kg)
Digital Meter Display
- 3.5" (9 cm) liquid crystal display (LCD)
Data Storage Capacity
- 20,000 samples
Output
- Digital: USB serial data to PC, printer or USB flash drive
- Analog: 4-20mA current loop (requires external power source)
- Accurate to 0.3% of output
Certifications
- TUV 61010, CE
Accuracy and Precision
Calibration Point | Accuracy** | Precision (RSD) |
1.0 ìg/m3 | 10% | 15% |
25 ìg/m3 | 5% | 3% |
100+ ìg/m3 | 5% | 3% |
- Regulatory detection compliance
- Regulatory clean up compliance
- Ambient air analysis
- Quality control
- Scrubber efficiency testing
- Accuracy check for other mercury vapor monitors and control systems
- Mercury vapor source detection
- Leak detection
- Portable mercury vapor detection (the Jerome® J405 is operated from an internal 12V battery source; for charging the batteries, an external AC power supply/charger is included)