Manufacturer: RKI Instruments
Part Number: EC-600
Order / Quote
RKI’s Model EC-600 is an indoor monitor that detects Carbon Monoxide (CO) with a range of 0 - 150 ppm. It’s a sleek low profile design which lends itself to laboratory or commercial applications. The EC-600 comes ready to operate with a simple wall mount bracket and 10 foot power cord. If Carbon Monoxide is present, the user is notified by an audible alarm tone and multicolored LED display.
The EC-600 uses a fast responding, low-cost plug-in style, electrochemical sensor. This long life sensor is field-replaceable with no special tools required.
Measuring Gas: Carbon Monoxide (CO) Sampling Method: Diffusion Physical Dimensions: 95(W) x 135(H) x 35(D) mm
Weight: Approx. 420 g (Approx. 220 g in case of DC 24V version) Display: 3 digits, 3 color LED (Green, Orange, Red)
Normal: Green Mounting: Wall mounting type (by using accessory mounting plate or mount at one switch box).
Cable Inlet: Up, down and left/right, or rear side. Environmental Operating Temperature: 0 - 40ºC (0 - 104ºF). Relative Humidity: Below 90% RH (non-condensing).
Sensors: Sensor Types Electrochemical Measuring Ranges: 0 - 150 ppm (1 ppm/digit).
Outputs:
Type of Alarms Gas Alarm: 2 level alarm (Latched mode/cancelled by reset switch) Trouble Alarm: Sensor connection trouble (Non-latched mode) Preset Alarm Levels 1st: 50 ppm, 2nd: 100 ppm Relays: AL1/AL2 Form A common, contact capacity: 125V 1A (Resistive load) Visual 1st Alarm: Flashing orange LED with gas display AL1 LED orange color flashing, intermittent buzzer sound.
2nd Alarm: Flashing red LED gas display AL2 LED red color flashing, intermittent buzzer sound.
Trouble Alarm: Red flashing display “D-**” (**shows error Number), short intermittent buzzer sound.
Power: AC 115 V 50/60 Hz
Power Consumption: Max 3.5 VA
Power Cable: 3 m accessory (standard)
Option: (DC 24 V, Power consumption: MAX 2.0 W)
Warranty One year materials and workmanship.
Carbon Monoxide and it’s reaction/poisoning to humans:
CO (ppm) |
Human reaction and poisoning |
---|---|
100 |
No noticeable effect after breathing in for a few hours. |
200 |
Slight headache is felt after breathing for about 1.5 hours. |
400-500 |
A headache, nausea and dizziness etc. are caused after breathing around 1 hour. |
500-1,000 |
Loss of consciousness breathing about 1 - 1.5 hours. |
1,500-2,000 |
A headache, dizziness, nausea will be severe after breathing for about 30 min. - 1 hour and a sense will be lost. |
10,000 |
Immediate death |
* Specifications subject to change without notice.
- Iron and Steel Industry
- Laboratories
- Boiler Rooms
- Garages
- Vehicle Service Areas
- Engine Testing
- Shipping/Receiving Docks
- Multi - Occupancy Residences