Manufacturer: RAE Systems
Order / Quote
The UltraRAE 3000 is the most advanced Compound-Specific Monitor on the market. Its Photoionization Detector’s (PID)extended range of 0.01 to 10,000 ppm in VOC mode and 10 ppb to 200 ppm in benzene-specific mode makes it an ideal instrument for applications, from entry pre-screening during refinery and plant maintenance to hazardous material response, marine spill response and refinery down-stream monitoring.
Key Features:
- Proven PID technology
- 3-second response in VOC mode or 60 seconds in compound-specific mode
- Extended range up to 10,000 ppm (in VOC mode) with improved linearity
- Built-in humidity sensor
- Automatic temperature-controlled sampling time calculation
- Highly specific readings, combining a 9.8eV UV lamp and RAE-Sep™ benzene tube
- New sampling probe design provides instant tube-breakthrough visibility
- Versatile VOC or Benzene-Specific modes
- Real-time wireless with built-in Bluetooth and optional RAELink3 portable modem
- Integrated RAE Systems Correction Factors list for more than 200 compounds
- Large graphic display
- Multi-language support
- Easy access to lamp, sensor and battery in seconds without tools
- Inexpensive analysis using low-cost RAE-Sep tubes vs. gas detection tubes
- Much less expensive than a portable GC, and no annual factory calibration is required
Size
- 10" L x 3.0" W x 2.5" H (25.5 x 7.6 x 6.4 cm)
Weight
- 26 oz (738 g)
Sensors
- Photoionization sensor with standard 9.8 eV or optional 10.6 eV or 11.7 eV lamps
Sensor Specifications
Range | Resolution | Response Time (T90) | |
VOCs | 0 to 99.99 ppm | 0.05 ppm | < 3 sec |
100 to 999.9 ppm | 0.1 ppm | < 3 sec | |
1000 to 9999 ppm | 1 ppm | < 3 sec | |
Benzene | 0 to 200 ppm | 0.05 ppm | < 60 sec |
Butadiene | 0 to 200 ppm | 0.05 ppm | < 60 sec |
Battery
- Rechargeable, external field-replaceable lithium-ion battery pack
- Alkaline battery adapter
Operating Hours
- 16 hours of operation
Display Graphic
- 4 lines, 28 x 43mm
Keypad
- 1 operation and 2 programming keys, 1 flashlight on/off button
Direct Readout
- VOCs as ppm by volume
- High and low values
- STEL and TWA
- Battery and shutdown voltage
- Date, time, temperature
Alarms
- 95dB buzzer (at 12"/30 cm) and flashing red LED to indicate exceeded preset limits:
- High: 3 beeps and flashes per second
- Low: 2 beeps and flashes per second
- STEL and TWA: 1 beep and flash per second
- Alarms latching with manual override or automatic reset
- Additional diagnostic alarm and display message for low battery and pump stall
EMI/RFI
- Highly resistant to EMI/RFI. Compliant with EMC directive (2004/108/EC); R & TTE directive (1999/5/EC)
IP Rating
- IP-65, unit running
Datalogging
- Standard 6 months at one-minute intervals
Calibration
- 2-point or 3-point calibration for zero and span. Calibration memory for 8 calibration gases, alarm limits, span values and calibration dates
Sampling Pump
- Internal, integrated flow rate at 400 cc/min
- Sample from 100' (30m) horizontally and vertically
Low Flow Alarm
- Auto shut-off pump at low-flow condition
Communication
- Download data and upload instrument setup from PC through charging cradle
- Wireless data transmission through built-in BlueTooth™
Frequency for RAELink3 Optional Modem
- 902 to 928 MHz (License free), 2.400 to 2.4835 GHz (license-free), 433 MHz, 869 MHz
RF Range
- Up to 15'/4.5m (2.400 GHz - Bluetooth™), extendable with RAELink3 modem to 2 miles (3.2km)
Hazardous Area Approval
- US and Canada: Classified as Intrinsically Safe for use in Class I, Division 1 Groups A, B, C, D
- Europe: ATEX II 2G EEx ia IIC T4
Operating Temperature
- -4° to 113° F (-20° to 50°C)
Humidity
- 0% to 95% relative humidity (non-condensing)
Attachments
- Durable bright red rubber boot
Warranty
- 3 years for 10.6 eV lamp, 1 year for 9.8. eV lamp, pump, battery, sensor and instrumen
Gas Monitor - Range / Resolution / Response Time (T90)
- VOCs:
- 0 to 99.99 ppm / 0.010 ppm / < 3 sec
- 100 to 999.9 ppm / 0.1 ppm / < 3 sec
- 1000 to 9999 ppm / 1 ppm / < 3 sec
- Benzene: 0 to 200 ppm / 0.010 ppm / < 60 sec
- Butadiene: 0 to 200 ppm / 0.010 ppm / < 60 sec
- Confined space entry pre-screening during refinery and plant maintenance
- Hazardous material response
- Marine spill response
- Refinery down-stream monitoring
- Plant overhaul